FGT FGT
產品介紹

FML500 FML Ultrasonic Flow Meter

prod cover
・Clean structure, with a new PFA material for the parts in contact with the liquid.
・Straight flow path ensures low pressure loss, making mainte-nance easier.
・Small, lightweight and compact.
・With its built-in display, flow rates can be measured by just con-necting to a DC24V power source.
・High viscosity liquids can be measured. (*Please contact us for details.)

Ultrasonic Flow Meter,liquid flow meter,water flow meter

The FML-500 is a straight tube type ultrasonic flow meter for liquids. A new PFA material with excellent chemical resistance is used for parts in contact with the liquid, and the simple straight design facilitates maintenance without any obstacles inside the tube. It comes with a built-in display and the flow rate can be measured by connecting it to a power source. Flow rates up to a full scale of 5 L/min can be measured with high accuracy.

 

Features

・Clean structure, with a new PFA material for the parts in contact with the liquid.
・Straight flow path ensures low pressure loss, making mainte-nance easier.
・Small, lightweight and compact.
・With its built-in display, flow rates can be measured by just con-necting to a DC24V power source.
・High viscosity liquids can be measured. (*Please contact us for details.) 

 

Standard Specifications

Applicable liquids Water, purified water (no bubbles)
*Please contact us for other liquids.
Fluid sonic velocity 1300 m/s to 1600 m/s
Fluid temperature range 15 to 50℃
Measurement range 0 to 5 L/min
Accuracy Refer to Table 1.
Material in contact with liquid New PFA
Proof pressure 0.5 MPa (at 23℃)
Process connection 6 mm tube end
Dedicated cable length 3 m
Cable sheath PVC
Structure IP64 or equivalent
Ambient temperature 5 to 50℃ (no condensation allowed)
Ambient humidity 10 to max. 85% RH (no condensation allowed)
Mounting position Vertical, horizontal, diagonal
Weight 200 g (main unit)
       
     

 

Electrical Specifications

Measurement method Ultrasonic propagation time-difference calculation method
Output 1) Flow rate output 4 to 20 mA (Load resistance: 500Ω or less)
2) Flow rate alarm
output
Two open collector output points
Rated load: 30 VDC, 20 mA, Action: Comparison method
Display 4-digit 7-segment LED
Indicated contents Instantaneous flow, total flow
Alarm output monitor LED two-point display (Instantaneous flow alarm, total flow alarm)
Parameter setting By four key switches on panel
Required power supply 24 VDC ±5%
Power consumption 150 mA or less

Table 1 Measurement Accuracy (Water, 23°C)

Measurement range 0 to 5 L/min
Flow range 0 to 0.20 L/min to 0 to 5.00 L/min
Measurement accuracy Flow velocity 1 m/s ±30 mL/min (less than 0.8 L/min)
1 to 2 m/s ±2.5% FS (0.8 to 1.5 L/min)
2 to 3 m/s ±2.0% FS (1.6 to 2.2 L/min)
3 to 6.6 m/s ±1.5% FS (2.3 to 5 L/min)
     

 

Measurement range:0 to 5 L/min Flow range:0 to 0.20 L/min to 0 to 5.00 L/min Measurement accuracy: Flow velocity 1 m/s ±30 mL/min (less than 0.8 L/min) 1 to 2 m/s ±2.5% FS (0.8 to 1.5 L/min) 2 to 3 m/s ±2.0% FS (1.6 to 2.2 L/min) 3 to 6.6 m/s ±1.5% FS (2.3 to 5 L/min)